HRGP-110 T5 LPG
109 kVA Generator set Rental
Powered by: PSI
Alternator: STAMFORD
Three phase | 50 Hz | LPG |
- Engine Specifications 1.500 r.p.m.
- Rated Engine Output: 96,2kW prp ; 107,7kW standby
- Manufacturer: PSI
- Model: 8.8L NA
- Engine Type: 4-stroke Otto Cycle
- Injection Type: Carburization
- Aspiration Type: Natural
- Number of cylinders and arrangement: 8-V
- Bore and Stroke: 110,5 x 114,3 mm
- Displacement: 8,8 L
- Cooling System: Coolant
- Lube Oil Specifications: API ≥SM, SAE 5W30
- Compression Ratio: 10,1:1
- Total oil capacity including tubes, filters 7,6 L
- Governor Type Electrical
- Air Filter Type Dry
- LPG-liquefied petrol gas engine
- 4-stroke cycle
- Water-cooled
- 12V electrical system
- Dry air filter
- Radiator with pusher fan
- Electronic governor
- Hot parts protection
- Moving parts protection
- HTW sender (Optional)
- LOP sender (Optional)
- Generator: STAMFORD
- Model: UCI274D
- Poles: 4
- Connection type (standard): Star-series
- Mounting type: S-3 11"1/2
- Insulation: H class
- Enclosure (according IEC-34-5): IP23
- Exciter system: Self-excited, brushless
- Voltage regulator: A.V.R. (Electronic)
- Bracket type: Single bearing
- Coupling system: Flexible disc
- Coating type: Standard (Vacuum impregnation)
- - SOUNDPROOFED VERSION.
- Steel chassis
- Anti-vibration shock absorbers
- External emergency stop switch
- Bodywork made from high quality steel plate
- High mechanical strength
- Low noise emissions level
- Soundproofing provided by high-density volcanic rock wool
- Epoxy polyester powder coating
- Full access for maintenance (water, oil and filters, no need to remove the canopy)
- Reinforced lifting hooks for crane hoisting
- Chassis drain plug
- Steel residential silencer -35db(A) attenuation.
- Oil sump extraction kit
- IP Protection according to ISO 8528-13:2016
- - GAS RAMP.
- Manual shut-off valve
- Gas filter
- Double solenoid valve
- Primary pressure regulator
- Secondary pressure regulator (Zero pressure regulator)
- Low pressure switch
- Inlet pressure manometer
- Outlet pressure manometer
- Special Start/Stop sequence
- High pressure regulator (Optional)
- High pressure switch (Optional)
- - ELECTRICAL SYSTEM.
- Electric control and power panel with measurements devices and control unit (according to necessity and configuration)
- Adjustable earth leakage protection (time & sensitivity) standard in M5 and AS5, with thermal magnetic protection
- Battery charger (standard on gensets with automatic control panels)
- Heating resistor (standard on sets with automatic control panels)
- Battery charger alternator with ground connection
- Starter battery/ies installed (cables and bracket included)
- Ground connection electrical installation with connection ready for ground spike (not supplied)
- Battery Switch (Optional)
- - EXHAUST SYSTEM.
- Maximum exhaust temperature: 705 ºC
- Exhaust Gas Flow: 18,76 m3/min
- Maximum allowed back pressure: 10,2 kPa
- Exhaust Flange Size (external diameter): 90 mm
- - NECESSARY AMOUNT OF AIR.
- Intake air flow: 348,6 m3/h
- Alternator fan air flow: 0,514 m3/s
- - STARTING SYSTEM.
- Starting power: 1,7 kW
- Starting power: 2,31 CV
- Recommended battery: 115 Ah
- Auxiliary Voltage: 12 Vdc
- - FUEL SYSTEM
- Fuel Oil Specifications: LPG
- - DIMENSIONS.
- Length: 2.810 mm
- Height: 2.360 mm
- Width: 1.150 mm
- Maximum shipping volume: 7,63 m3
- Weight with liquids in radiator and sump: 2.608 kg
- Sound pressure level: 71 ± 2,4 dB(A)@7m
Power
kVA
109
121
Prime power (109 - 109)
Stand by (121 - 121)
Stand by (121 - 121)
kW
87
97
Prime power (87 - 87)
Stand by (97 - 97)
Stand by (97 - 97)
Sound level
dB
Distance (m)
Distance (m)
dimensions
Long (A)
281
Width (B)
115
High (C)
236
Long (A)
110,63
Width (B)
45,28
High (C)
92,91
Weight
Weight with liquid in radiator and carter
2.608 5.750,64
2.608 5.750,64
Fuel capacity
0