HRGP-110 T5 LPG

 

HRGP-110 T5 LPG

109 kVA Generator set Rental

Powered by: PSI
Alternator: STAMFORD

 

Three phase | 50 Hz | LPG |

 

 

  • Engine Specifications 1.500 r.p.m.
  • Rated Engine Output: 96,2kW prp ; 107,7kW standby
  • Manufacturer: PSI
  • Model: 8.8L NA
  • Engine Type: 4-stroke Otto Cycle
  • Injection Type: Carburization
  • Aspiration Type: Natural
  • Number of cylinders and arrangement: 8-V
  • Bore and Stroke: 110,5 x 114,3 mm
  • Displacement: 8,8 L
  • Cooling System: Coolant
  • Lube Oil Specifications: API ≥SM, SAE 5W30
  • Compression Ratio: 10,1:1
  • Total oil capacity including tubes, filters 7,6 L
  • Governor Type Electrical
  • Air Filter Type Dry
  • LPG-liquefied petrol gas engine
  • 4-stroke cycle
  • Water-cooled
  • 12V electrical system
  • Dry air filter
  • Radiator with pusher fan
  • Electronic governor
  • Hot parts protection
  • Moving parts protection
  • HTW sender (Optional)
  • LOP sender (Optional)
  • Generator: STAMFORD
  • Model: UCI274D
  • Poles: 4
  • Connection type (standard): Star-series
  • Mounting type: S-3 11"1/2
  • Insulation: H class
  • Enclosure (according IEC-34-5): IP23
  • Exciter system: Self-excited, brushless
  • Voltage regulator: A.V.R. (Electronic)
  • Bracket type: Single bearing
  • Coupling system: Flexible disc
  • Coating type: Standard (Vacuum impregnation)
  • - SOUNDPROOFED VERSION.
  • Steel chassis
  • Anti-vibration shock absorbers
  • External emergency stop switch
  • Bodywork made from high quality steel plate
  • High mechanical strength
  • Low noise emissions level
  • Soundproofing provided by high-density volcanic rock wool
  • Epoxy polyester powder coating
  • Full access for maintenance (water, oil and filters, no need to remove the canopy)
  • Reinforced lifting hooks for crane hoisting
  • Chassis drain plug
  • Steel residential silencer -35db(A) attenuation.
  • Oil sump extraction kit
  • IP Protection according to ISO 8528-13:2016
  • - GAS RAMP.
  • Manual shut-off valve
  • Gas filter
  • Double solenoid valve
  • Primary pressure regulator
  • Secondary pressure regulator (Zero pressure regulator)
  • Low pressure switch
  • Inlet pressure manometer
  • Outlet pressure manometer
  • Special Start/Stop sequence
  • High pressure regulator (Optional)
  • High pressure switch (Optional)
  • - ELECTRICAL SYSTEM.
  • Electric control and power panel with measurements devices and control unit (according to necessity and configuration)
  • Adjustable earth leakage protection (time & sensitivity) standard in M5 and AS5, with thermal magnetic protection
  • Battery charger (standard on gensets with automatic control panels)
  • Heating resistor (standard on sets with automatic control panels)
  • Battery charger alternator with ground connection
  • Starter battery/ies installed (cables and bracket included)
  • Ground connection electrical installation with connection ready for ground spike (not supplied)
  • Battery Switch (Optional)
  • - EXHAUST SYSTEM.
  • Maximum exhaust temperature: 705 ºC
  • Exhaust Gas Flow: 18,76 m3/min
  • Maximum allowed back pressure: 10,2 kPa
  • Exhaust Flange Size (external diameter): 90 mm
  • - NECESSARY AMOUNT OF AIR.
  • Intake air flow: 348,6 m3/h
  • Alternator fan air flow: 0,514 m3/s
  • - STARTING SYSTEM.
  • Starting power: 1,7 kW
  • Starting power: 2,31 CV
  • Recommended battery: 115 Ah
  • Auxiliary Voltage: 12 Vdc
  • - FUEL SYSTEM
  • Fuel Oil Specifications: LPG
  • - DIMENSIONS.
  • Length: 2.810 mm
  • Height: 2.360 mm
  • Width: 1.150 mm
  • Maximum shipping volume: 7,63 m3
  • Weight with liquids in radiator and sump: 2.608 kg
  • Sound pressure level: 71 ± 2,4 dB(A)@7m

Power


kVA

109
 
121
Prime power  (109 - 109)
Stand by  (121 - 121)

kW

87
 
97
Prime power  (87 - 87)
Stand by  (97 - 97)
 

Sound level

 dB
 Distance (m)

 
 

dimensions


 
dimensions
Long (A)
281
Width (B)
115
High (C)
236
 

Weight


 
Weight
Weight with liquid in radiator and carter

2.608
 

Fuel capacity