HGP-880 T6 NG
894 kVA Generator set Open Skid
Powered by: PSI
Alternator: MECC ALTE
Three phase | 60 Hz | Natural Gas | Complying EPA
- Engine Specifications 1.800 r.p.m.
- Rated Engine Output: 740kW prp ; 880kW standby
- Manufacturer: PSI
- Model: 40L
- Engine Type: 4-stroke Otto Cycle
- Injection Type: Direct
- Aspiration Type: Turbocharged and after-cooled
- Number of cylinders and arrangement: 12-V
- Bore and Stroke: 150 x 185 mm
- Displacement: 39,2 L
- Cooling System: Coolant
- Lube Oil Specifications: SAE 15W40; API CD or CE
- Compression Ratio: 10,5:1
- Fuel Consumption ESP: 2710 kW
- Fuel Consumption 100% PRP: 2336 kW
- Fuel Consumption 75 % PRP: 1805 kW
- Fuel Consumption 50 % PRP: 1294 kW
- Fuel Consumption 25 % PRP: 795 kW
- Total oil capacity: 146 L
- Total coolant capacity: 172 L
- Governor Type Electrical
- Air Filter Type Dry
- Natural Gas engine
- 4-stroke cycle
- Water-cooled
- Radiator with pusher fan
- HTW sender
- LOP sender
- Electronic governor
- Hot parts protection
- Moving parts protection
- Generator: MECC ALTE
- Model: ECO40 VL/4 B
- Poles: 4
- Connection type (standard): Star - Parallel
- Mounting type: S-0 18''
- Insulation: H class
- Enclosure (according IEC-34-5): IP23
- Exciter system: Self-excited, brushless
- Voltage regulator: A.V.R. (Electronic)
- Bracket type: Single bearing
- Coupling system: Flexible disc
- Coating type: Standard (Vacuum impregnation)
- - OPEN SET VERSION.
- Emergency stop button
- Steel chassis
- Anti-vibration shock absorbers
- Steel industrial silencer -15db(A) attenuation
- Steel residential silencer -35db(A) attenuation.
- - GAS RAMP.
- Manual shut-off valve
- Gas filter
- Double solenoid valve
- High pressure regulator
- Primary pressure regulator
- Low pressure switch
- High pressure switch
- Valve (tightness) testing system
- Inlet pressure manometer
- Outlet pressure manometer
- Special Start/Stop sequence
- - ELECTRICAL SYSTEM.
- Electric control and power panel with measurements devices and control unit (according to necessity and configuration)
- Battery Switch
- Adjustable earth leakage protection (time & sensitivity) standard in M12, with thermal magnetic protection
- Battery charger (standard on gensets with automatic control panels)
- Heating resistor (standard on sets with automatic control panels)
- Starter battery/ies installed (cables and bracket included)
- Ground connection electrical installation with connection ready for ground spike (not supplied)
- - EXHAUST SYSTEM.
- Maximum exhaust temperature: 670 ºC
- Exhaust Gas Flow: 139 m3/min
- Maximum allowed back pressure: 13 kPa
- - NECESSARY AMOUNT OF AIR.
- Intake air flow: 2700 m3/h
- Alternator fan air flow: 1,08 m3/s
- - STARTING SYSTEM.
- Starting power: 10 kW
- Starting power: 13,6 CV
- Recommended battery: 75 x 4 Ah
- Auxiliary Voltage: 24 Vdc
- - FUEL SYSTEM
- Fuel Oil Specifications: Natural Gas
- - DIMENSIONS.
- Length: 4.500 mm
- Height: 2.400 mm
- Width: 2.200 mm
- Maximum shipping volume: 23,76 m3
Power
kVA
894
970
Prime power (95 - 1183)
Stand by (105 - 1322)
Stand by (105 - 1322)
kW
715
776
Prime power (76 - 947)
Stand by (84 - 1058)
Stand by (84 - 1058)
Sound level
dB
Distance (m)
Distance (m)
dimensions
Long (A)
450
Width (B)
220
High (C)
240
Long (A)
177,17
Width (B)
86,61
High (C)
94,49
Weight
Weight with liquid in radiator and carter
0 0
0 0
Fuel capacity
0
0