HRGO-80 T5 LPG

 

HRGO-80 T5 LPG

80 kVA Generator set Rental

Powered by: FORD
Alternator: STAMFORD

 

Three phase | 50 Hz | LPG | Stage V

 

 

  • Engine Specifications 1.500 r.p.m.
  • Rated Engine Output: 70,8kW prp ; 78,8kW standby
  • Manufacturer: FORD
  • Model: WSG873
  • Engine Type: 4-stroke Miller Cycle
  • Injection Type: Carburization
  • Aspiration Type: Natural
  • Number of cylinders and arrangement: 8-V
  • Bore and Stroke: 107,2 x 101 mm
  • Displacement: 7,3 L
  • Cooling System: Liquid (water + 50% glycol)
  • Lube Oil Specifications: API ≥SH, SAE 10W-30
  • Compression Ratio: 10,5
  • Total oil capacity including tubes, filters 7,5 L
  • Governor Type Electrical
  • Air Filter Type In oil bath
  • LPG Engine (Optioon of working with NG, to consult)
  • 4-stroke cycle
  • Water-cooled
  • 12V electrical system
  • Dry air filter
  • Radiator with pusher fan
  • HTW sender
  • LOP sender
  • Electronic governor
  • Hot parts protection
  • Moving parts protection
  • Generator: STAMFORD
  • Model: UCI224G
  • Poles: 4
  • Connection type (standard): Star-series
  • Mounting type: S-3 11"1/2
  • Insulation: H class
  • Enclosure (according IEC-34-5): IP23
  • Exciter system: Self-excited, brushless
  • Voltage regulator: A.V.R. (Electronic)
  • Bracket type: Single bearing
  • Coupling system: Flexible disc
  • Coating type: Standard (Vacuum impregnation)
  • - SOUNDPROOFED VERSION.
  • Steel chassis
  • Anti-vibration shock absorbers
  • External emergency stop switch
  • Bodywork made from high quality steel plate
  • High mechanical strength
  • Low noise emissions level
  • Soundproofing provided by high-density volcanic rock wool
  • Epoxy polyester powder coating
  • Full access for maintenance (water, oil and filters, no need to remove the canopy)
  • Reinforced lifting hooks for crane hoisting
  • Watertight chassis (acts as a double barrier against liquid retention)
  • Chassis drain plug
  • Steel residential silencer -35db(A) attenuation.
  • Oil sump extraction kit
  • IP Protection according to ISO 8528-13:2016
  • - GAS RAMP.
  • Gas filter
  • Double solenoid valve
  • High pressure regulator
  • Low pressure switch
  • High pressure switch
  • Inlet pressure manometer
  • Outlet pressure manometer
  • Special Start/Stop sequence
  • - ELECTRICAL SYSTEM.
  • Electric control and power panel with measurements devices and control unit (according to necessity and configuration)
  • Adjustable earth leakage protection (time & sensitivity) standard in M5 and AS5, with thermal magnetic protection
  • Battery charger (standard on gensets with automatic control panels)
  • Heating resistor (standard on sets with automatic control panels)
  • Battery charger alternator with ground connection
  • Starter battery/ies installed (cables and bracket included)
  • Ground connection electrical installation with connection ready for ground spike (not supplied)
  • Battery Switch (Optional)
  • - EXHAUST SYSTEM.
  • Exhaust Gas Flow: 14,17 m3/min
  • Maximum allowed back pressure: 20,32 kPa
  • Exhaust Flange Size (external diameter): 90 mm
  • - NECESSARY AMOUNT OF AIR.
  • Intake air flow: 279,225 m3/h
  • Alternator fan air flow: 0,216 m3/s
  • - STARTING SYSTEM.
  • - FUEL SYSTEM
  • Fuel Oil Specifications: LPG
  • - DIMENSIONS.
  • Length: 2.810 mm
  • Height: 2.358 mm
  • Width: 1.150 mm
  • Maximum shipping volume: 7,62 m3
  • Sound pressure level: 61 ± 2,4 dB(A)@7m

Power


kVA

80
 
89
Prime power  (26 - 97)
Stand by  (29 - 108)

kW

64
 
71
Prime power  (21 - 77)
Stand by  (23 - 86)
 

Sound level

 dB
 Distance (m)

 
 

dimensions


 
dimensions
Long (A)
281
Width (B)
115
High (C)
235,80
 

Weight


 
Weight
Weight with liquid in radiator and carter

0
 

Fuel capacity