HTW-780 T5

 

HTW-780 T5

775 kVA Generator set Open Skid

Powered by: MITSUBISHI
Alternator: STAMFORD

 

Three phase | 50 Hz | Diesel |

 

 

  • Engine Specifications 1.500 r.p.m.
  • Rated Engine Output: 657kW prp ; 724kW standby
  • Manufacturer: MITSUBISHI
  • Model: S12A2 PTA
  • Engine Type: 4-stroke diesel
  • Injection Type: Direct
  • Aspiration Type: Turbocharged and after-cooled
  • Number of cylinders and arrangement: 12-V
  • Bore and Stroke: 150 x 160 mm
  • Displacement: 33,93 L
  • Cooling System: Water
  • Lube Oil Specifications: API CD or CF SAE 30 or SAE 40
  • Compression Ratio: 14,5:1
  • Fuel Consumption ESP: 183,19 l/h
  • Fuel Consumption 100% PRP: 166,24 l/h
  • Fuel Consumption 75 % PRP: 125,46 l/h
  • Fuel Consumption 50 % PRP: 88,31 l/h
  • Fuel Consumption 25 % PRP: 50,13 l/h
  • Lube oil consumption with full load: 0,8
  • Total oil capacity including tubes, filters 120 L
  • Total coolant capacity: 215 L
  • Governor Type Electrical
  • Air Filter Type Dry
  • Inner diameter exhaust pipe: 212 mm
  • Oil temperature sensor
  • Low coolant level sensor
  • Exhaust gas compensator
  • Diesel engine
  • 4-stroke cycle
  • Water-cooled
  • 24V electrical system
  • Standard air filter
  • Standard fuel filter
  • Standard oil filter
  • Radiator with pusher fan
  • HTW sender
  • LOP sender
  • Electronic governor
  • Hot parts protection
  • Moving parts protection
  • Generator: STAMFORD
  • Model: HCI634G
  • Poles: 4
  • Connection type (standard): Star-series
  • Mounting type: S-0 18''
  • Insulation: H class
  • Enclosure (according IEC-34-5): IP23
  • Exciter system: Self-excited, brushless
  • Voltage regulator: A.V.R. (Electronic)
  • Bracket type: Single bearing
  • Coupling system: Flexible disc
  • Coating type: Standard (Vacuum impregnation)
  • - OPEN SET VERSION.
  • Steel chassis
  • Emergency stop button
  • Oil sump extraction kit
  • Anti-vibration shock absorbers
  • Chassis with integrated fuel tank
  • Fuel level gauge
  • Fuel tank drain plug
  • - ELECTRICAL SYSTEM.
  • Electric control and power panel with measurements devices and control unit (according to necessity and configuration)
  • Connection panel wired to the safety protection (open thermal magnetic protection and alarm)
  • Maintenance-free and anti-explosion battery
  • Battery Switch
  • Battery charger (standard on gensets with automatic control panels)
  • Water Jacket Heater with single phase pump
  • Battery charger alternator with ground connection
  • Starter battery/ies installed (cables and bracket included)
  • Ground connection electrical installation with connection ready for ground spike (not supplied)
  • - EXHAUST SYSTEM.
  • Maximum exhaust temperature: 500 ºC
  • Exhaust Gas Flow: 170 m3/min
  • Maximum allowed back pressure: 600 mm H2o
  • Heat dissipated by exhaust pipe: 695,6 KCal/Kwh
  • - NECESSARY AMOUNT OF AIR.
  • Intake air flow: 3840 m3/h
  • Cooling Air Flow: 19 m3/s
  • Alternator fan air flow: 1,614 m3/s
  • - STARTING SYSTEM.
  • Starting power: 7,5 x 2 kW
  • Starting power: 10,2 x 2 CV
  • Recommended battery: 300 Ah
  • Auxiliary Voltage: 24 Vdc
  • Starter current peak: 720 A
  • Nominal starter current: 380 A
  • - FUEL SYSTEM
  • Fuel Oil Specifications: Diesel
  • Maximum power suction pump: 75 mm Hg
  • Maximum return feed pump: 150 mm Hg
  • - DIMENSIONS.
  • Length: 4.140 mm
  • Height: 2.052 mm
  • Width: 1.816 mm
  • Maximum shipping volume: 15,43 m3
  • Weight with liquids in radiator and sump: 6.673 kg

Power


kVA

775
 
853
Prime power  (670 - 2555)
Stand by  (738 - 2816)

kW

620
 
682
Prime power  (536 - 2044)
Stand by  (590 - 2253)
 

Sound level

 dB
 Distance (m)

 
 

dimensions


 
dimensions
Long (A)
414
Width (B)
181,60
High (C)
205,20
 

Weight


 
Weight
Weight with liquid in radiator and carter

6.673
 

Fuel capacity