HSW-450 T5

 

HSW-450 T5

461 kVA Generator set Open Skid

Powered by: SCANIA
Alternator: STAMFORD

 

Three phase | 50 Hz | Diesel |

 

 

  • Engine Specifications 1.500 r.p.m.
  • Rated Engine Output: 393kW prp ; 428kW standby
  • Manufacturer: SCANIA
  • Model: DC13-72A(02-13)
  • Engine Type: 4-stroke diesel
  • Injection Type: Direct
  • Aspiration Type: Turbocharged and after-cooled
  • Number of cylinders and arrangement: 6-L
  • Bore and Stroke: 130 x 160 mm
  • Displacement: 12,7 L
  • Cooling System: Coolant
  • Lube Oil Specifications: ACEA E3,E4,E5 or E7
  • Compression Ratio: 16,3:1
  • Fuel Consumption ESP: 97,79 l/h
  • Fuel Consumption 100% PRP: 87,16 l/h
  • Fuel Consumption 75 % PRP: 64,32 l/h
  • Fuel Consumption 50 % PRP: 43,35 l/h
  • Lube oil consumption with full load: 0,3
  • Total oil capacity: 38 L
  • Total coolant capacity: 38 L
  • Governor Type Electrical
  • Air Filter Type Dry
  • Inner diameter exhaust pipe: 90 mm
  • Diesel engine
  • 4-stroke cycle
  • Water-cooled
  • 24V electrical system
  • Water separator filter (visible level)
  • Dry air filter
  • Radiator with pusher fan
  • Radiator water level sensor
  • HTW sender
  • LOP sender
  • Electronic governor
  • Hot parts protection
  • Moving parts protection
  • Generator: STAMFORD
  • Model: HCI544C
  • Poles: 4
  • Connection type (standard): Star-series
  • Mounting type: S-1 14"
  • Insulation: H class
  • Enclosure (according IEC-34-5): IP23
  • Exciter system: Self-excited, brushless
  • Voltage regulator: A.V.R. (Electronic)
  • Bracket type: Single bearing
  • Coupling system: Flexible disc
  • Coating type: Standard (Vacuum impregnation)
  • - OPEN SET VERSION.
  • Steel chassis
  • Emergency stop button
  • Oil sump extraction kit
  • Anti-vibration shock absorbers
  • Chassis with integrated fuel tank
  • Fuel level gauge
  • Fuel tank drain plug
  • Steel industrial silencer -15db(A) attenuation
  • Fuel transfer pump (Optional)
  • Steel residential silencer -35db(A) attenuation. (Optional)
  • - ELECTRICAL SYSTEM.
  • Electric control and power panel with measurements devices and control unit (according to necessity and configuration)
  • Battery Switch
  • Adjustable earth leakage protection (time & sensitivity) standard in M5 and AS5, with thermal magnetic protection
  • Battery charger (standard on gensets with automatic control panels)
  • Heating resistor (standard on sets with automatic control panels)
  • Battery charger alternator with ground connection
  • Starter battery/ies installed (cables and bracket included)
  • Ground connection electrical installation with connection ready for ground spike (not supplied)
  • - EXHAUST SYSTEM.
  • Maximum exhaust temperature: 536 ºC
  • Exhaust Gas Flow: 0,567 kg/s
  • Maximum allowed back pressure: 100 mbar
  • Heat dissipated by exhaust pipe: 607,14 KCal/Kwh
  • - NECESSARY AMOUNT OF AIR.
  • Intake air flow: 1600 m3/h
  • Cooling Air Flow: 9,58 m3/s
  • Alternator fan air flow: 1,035 m3/s
  • - STARTING SYSTEM.
  • Starting power: 5,5 kW
  • Starting power: 7,48 CV
  • Auxiliary Voltage: 24 Vdc
  • - FUEL SYSTEM
  • Fuel Oil Specifications: Diesel
  • Fuel Tank: 740 L
  • - DIMENSIONS.
  • Length: 3.600 mm
  • Height: 2.090 mm
  • Width: 1.460 mm
  • Maximum shipping volume: 10,99 m3
  • Weight with liquids in radiator and sump: 2.917 kg
  • Fuel tank capacity: 740 L
  • Autonomy: 12 Hours

Power


kVA

461
 
501
Prime power  (250 - 700)
Stand by  (275 - 711)

kW

369
 
401
Prime power  (200 - 560)
Stand by  (220 - 569)
 

Sound level

 dB
 Distance (m)

 
 

dimensions


 
dimensions
Long (A)
360
Width (B)
146
High (C)
209
 

Weight


 
Weight
Weight with liquid in radiator and carter

2.917
 

Fuel capacity


 
 
740