HGO-25 M5 NG

 

HGO-25 M5 NG

23 kVA Generator set Open Skid

Powered by: FORD
Alternator: STAMFORD

 

Single phase | 50 Hz | Natural Gas |

 

 

  • Engine Specifications 1.500 r.p.m.
  • Rated Engine Output: 22,6kW prp ; 24,8kW standby
  • Manufacturer: FORD
  • Model: MSG425
  • Engine Type: 4-stroke Otto Cycle
  • Injection Type: Carburization
  • Aspiration Type: Natural
  • Number of cylinders and arrangement: 4-L
  • Bore and Stroke: 89 x 100 mm
  • Displacement: 2,5 L
  • Cooling System: Coolant
  • Lube Oil Specifications: API SJ/SH, SAE 5W-20
  • Compression Ratio: 9,7:1
  • Fuel Consumption 100% PRP: 254.23 cfh
  • Total oil capacity including tubes, filters 6,3 L
  • Governor Type Electrical
  • Air Filter Type Dry
  • Natural Gas engine
  • 4-stroke cycle
  • Water-cooled
  • 12V electrical system
  • Dry air filter
  • Radiator with pusher fan
  • HTW sender
  • LOP sender
  • Electronic governor
  • Hot parts protection
  • Moving parts protection
  • Generator: STAMFORD
  • Model: S1L2.N1
  • Poles: 4
  • Connection type (standard): Double delta
  • Mounting type: S-4 10"
  • Insulation: H class
  • Enclosure (according IEC-34-5): IP23
  • Exciter system: Self-excited, brushless
  • Voltage regulator: A.V.R. (Electronic)
  • Bracket type: Single bearing
  • Coupling system: Flexible disc
  • Coating type: Standard (Vacuum impregnation)
  • - OPEN SET VERSION.
  • Steel chassis
  • Emergency stop button
  • Anti-vibration shock absorbers
  • Steel industrial silencer -15db(A) attenuation
  • Steel residential silencer -35db(A) attenuation. (Optional)
  • - GAS RAMP.
  • Gas filter
  • Double solenoid valve
  • High pressure regulator
  • Primary pressure regulator
  • Low pressure switch
  • Inlet pressure manometer
  • Outlet pressure manometer
  • Special Start/Stop sequence
  • High pressure switch (Optional)
  • - ELECTRICAL SYSTEM.
  • Electric control and power panel with measurements devices and control unit (according to necessity and configuration)
  • Adjustable earth leakage protection (time & sensitivity) standard in M5 and AS5, with thermal magnetic protection
  • Battery charger (standard on gensets with automatic control panels)
  • Heating resistor (standard on sets with automatic control panels)
  • Battery charger alternator with ground connection
  • Starter battery/ies installed (cables and bracket included)
  • Ground connection electrical installation with connection ready for ground spike (not supplied)
  • Battery Switch (Optional)
  • - EXHAUST SYSTEM.
  • Exhaust Gas Flow: 4,9 m3/min
  • Maximum allowed back pressure: 20,32 kPa
  • - NECESSARY AMOUNT OF AIR.
  • Intake air flow: 297,3 m3/h
  • Cooling Air Flow: 1,2 m3/s
  • Alternator fan air flow: 0,176 m3/s
  • - STARTING SYSTEM.
  • Recommended battery: 95 Ah
  • Auxiliary Voltage: 12 Vdc
  • - FUEL SYSTEM
  • Fuel Oil Specifications: Natural Gas
  • - DIMENSIONS.
  • Length: 1.750 mm
  • Height: 1.487 mm
  • Width: 900 mm
  • Maximum shipping volume: 2,34 m3
  • Weight with liquids in radiator and sump: 745 kg

Power


kVA

23
 
25
Prime power  (22 - 80)
Stand by  (24 - 89)

kW

18.1
 
19.8
Prime power  (18.1 - 73)
Stand by  (19.8 - 81)
 

Sound level

 dB
 Distance (m)

 
 

dimensions


 
dimensions
Long (A)
175
Width (B)
90
High (C)
148,70
 

Weight


 
Weight
Weight with liquid in radiator and carter

745
 

Fuel capacity