HYW-310 T5

 

HYW-310 T5

300 kVA Generator set Open Skid

Powered by: YANMAR
Alternator: MECC ALTE

 

Three phase | 50 Hz | Diesel |

 

 

  • Engine Specifications 1.500 r.p.m.
  • Rated Engine Output: 275kW prp ; 299kW standby
  • Manufacturer: YANMAR
  • Model: 6F117TE4.GL
  • Engine Type: 4-stroke diesel
  • Injection Type: Direct
  • Aspiration Type: Turbocharged and after-cooled
  • Number of cylinders and arrangement: 6-L
  • Bore and Stroke: 117 x 135 mm
  • Displacement: 8,7 L
  • Cooling System: Liquid (water + 50% glycol)
  • Lube Oil Specifications: API CI-4, ACEA E4, E5, E6 or E7
  • Compression Ratio: 15,9:1
  • Fuel Consumption ESP: 72,4 l/h
  • Fuel Consumption 100% PRP: 56,6 l/h
  • Fuel Consumption 80 % PRP: 52,6 l/h
  • Fuel Consumption 50 % PRP: 37,3 l/h
  • Total oil capacity including tubes, filters 28 L
  • Total coolant capacity: 58 L
  • Governor Type Electrical
  • Air Filter Type Dry
  • Diesel engine
  • 4-stroke cycle
  • Water-cooled
  • 24V electrical system
  • Water separator filter (no visible level)
  • Dry air filter
  • Radiator with pusher fan
  • HTW sender
  • LOP sender
  • Electronic governor
  • Hot parts protection
  • Moving parts protection
  • Generator: MECC ALTE
  • Model: ECO38 2L/4 A
  • Poles: 4
  • Connection type (standard): Star-series
  • Mounting type: S-1 14"
  • Insulation: H class
  • Enclosure (according IEC-34-5): IP23
  • Exciter system: Self-excited, brushless
  • Voltage regulator: A.V.R. (Electronic)
  • Bracket type: Single bearing
  • Coupling system: Flexible disc
  • Coating type: Standard (Vacuum impregnation)
  • - OPEN SET VERSION.
  • Steel chassis
  • Emergency stop button
  • Oil sump extraction kit
  • Anti-vibration shock absorbers
  • Chassis with integrated fuel tank
  • Fuel level gauge
  • High mechanical strength
  • Epoxy polyester powder coating
  • Fuel tank drain plug
  • Steel industrial silencer -15db(A) attenuation
  • Fuel transfer pump (Optional)
  • Steel residential silencer -35db(A) attenuation. (Optional)
  • - ELECTRICAL SYSTEM.
  • Electric control and power panel with measurements devices and control unit (according to necessity and configuration)
  • Battery Switch
  • Adjustable earth leakage protection (time & sensitivity) standard in M5 and AS5, with thermal magnetic protection
  • Battery charger (standard on gensets with automatic control panels)
  • Heating resistor (standard on sets with automatic control panels)
  • Battery charger alternator with ground connection
  • Starter battery/ies installed (cables and bracket included)
  • Ground connection electrical installation with connection ready for ground spike (not supplied)
  • - EXHAUST SYSTEM.
  • Maximum exhaust temperature: 488 ºC
  • Exhaust Gas Flow: 0,39 kg/s
  • Maximum allowed back pressure: 5 kPa
  • - NECESSARY AMOUNT OF AIR.
  • Intake air flow: 1085 m3/h
  • Cooling Air Flow: 5,65 m3/s
  • Alternator fan air flow: 0,533 m3/s
  • - STARTING SYSTEM.
  • Starting power: 4,5 kW
  • Starting power: 6,12 CV
  • - FUEL SYSTEM
  • Fuel Oil Specifications: Diesel
  • Fuel Tank: 449 L
  • - DIMENSIONS.
  • Length: 3.000 mm
  • Height: 1.790 mm
  • Width: 1.160 mm
  • Maximum shipping volume: 6,23 m3
  • Weight with liquids in radiator and sump: 2.542 kg
  • Fuel tank capacity: 449 L
  • Autonomy: 9 Hours

Power


kVA

300
 
330
Prime power  (6 - 1280)
Stand by  (6.5 - 1364)

kW

240
 
264
Prime power  (6 - 1024)
Stand by  (6.5 - 1091)
 

Sound level

 dB
 Distance (m)

 
 

dimensions


 
dimensions
Long (A)
300
Width (B)
116
High (C)
179
 

Weight


 
Weight
Weight with liquid in radiator and carter

2.542
 

Fuel capacity


 
 
449