HGO-25 T5 NG
25 kVA Generator set Soundproof
Powered by: FORD
Alternator: MECC ALTE
Three phase | 50 Hz | Natural Gas | Complying EPA
- Engine Specifications 1.500 r.p.m.
- Rated Engine Output: 22,6kW prp ; 24,8kW standby
- Manufacturer: FORD
- Model: MSG425
- Engine Type: 4-stroke Otto Cycle
- Injection Type: Carburization
- Aspiration Type: Natural
- Number of cylinders and arrangement: 4-L
- Bore and Stroke: 89 x 100 mm
- Displacement: 2,5 L
- Cooling System: Coolant
- Lube Oil Specifications: API SJ/SH, SAE 5W-20
- Compression Ratio: 9,7:1
- Fuel Consumption 100% PRP: 254.23 cfh
- Total oil capacity including tubes, filters 6,3 L
- Governor Type Electrical
- Air Filter Type Dry
- Natural Gas engine
- 4-stroke cycle
- Water-cooled
- 12V electrical system
- Dry air filter
- Radiator with pusher fan
- HTW sender
- LOP sender
- Electronic governor
- Hot parts protection
- Moving parts protection
- Generator: MECC ALTE
- Model: ECP28 2L/4 A
- Poles: 4
- Connection type (standard): Star-series
- Mounting type: S-4 10"
- Insulation: H class
- Enclosure (according IEC-34-5): IP23
- Exciter system: Self-excited, brushless
- Voltage regulator: A.V.R. (Electronic)
- Bracket type: Single bearing
- Coupling system: Flexible disc
- Coating type: Standard (Vacuum impregnation)
- - SOUNDPROOFED VERSION.
- Steel chassis
- Anti-vibration shock absorbers
- External emergency stop switch
- Bodywork made from high quality steel plate
- High mechanical strength
- Low noise emissions level
- Soundproofing provided by high-density volcanic rock wool
- Epoxy polyester powder coating
- Full access for maintenance (water, oil and filters, no need to remove the canopy)
- Reinforced lifting hooks for crane hoisting
- Chassis drain plug
- Steel residential silencer -35db(A) attenuation.
- IP Protection according to ISO 8528-13:2016
- - GAS RAMP.
- Gas filter
- Double solenoid valve
- High pressure regulator
- Primary pressure regulator
- Low pressure switch
- Inlet pressure manometer
- Outlet pressure manometer
- Special Start/Stop sequence
- High pressure switch (Optional)
- - ELECTRICAL SYSTEM.
- Electric control and power panel with measurements devices and control unit (according to necessity and configuration)
- Adjustable earth leakage protection (time & sensitivity) standard in M5 and AS5, with thermal magnetic protection
- Battery charger (standard on gensets with automatic control panels)
- Heating resistor (standard on sets with automatic control panels)
- Battery charger alternator with ground connection
- Starter battery/ies installed (cables and bracket included)
- Ground connection electrical installation with connection ready for ground spike (not supplied)
- Battery Switch (Optional)
- - EXHAUST SYSTEM.
- Exhaust Gas Flow: 4,9 m3/min
- Maximum allowed back pressure: 20,32 kPa
- Exhaust Flange Size (external diameter): 65 mm
- - NECESSARY AMOUNT OF AIR.
- Intake air flow: 297,3 m3/h
- Cooling Air Flow: 1,2 m3/s
- Alternator fan air flow: 0,088 m3/s
- - STARTING SYSTEM.
- Recommended battery: 95 Ah
- Auxiliary Voltage: 12 Vdc
- - FUEL SYSTEM
- Fuel Oil Specifications: Natural Gas
- - DIMENSIONS.
- Length: 2.100 mm
- Height: 1.350 mm
- Width: 975 mm
- Maximum shipping volume: 2,76 m3
- Weight with liquids in radiator and sump: 880 kg
- Sound pressure level: 58 ± 2,4 dB(A)@7m
Power
kVA
25
27
Prime power (22 - 80)
Stand by (24 - 89)
Stand by (24 - 89)
kW
19.8
21
Prime power (18.1 - 73)
Stand by (19.8 - 81)
Stand by (19.8 - 81)
Sound level
dB
Distance (m)
Distance (m)
dimensions

Long (A)
210
Width (B)
97,50
High (C)
135
Long (A)
82,68
Width (B)
38,39
High (C)
53,15
Weight

Weight with liquid in radiator and carter
880 1.940,40
880 1.940,40
Fuel capacity
0