HMW-1145 T5

 

HMW-1145 T5

1135 kVA Generator set Open Skid

Powered by: MTU
Alternator: STAMFORD

 

Three phase | 50 Hz | Diesel |

 

 

  • Engine Specifications 1.500 r.p.m.
  • Rated Engine Output: 956,6kW prp ; 1056,6kW standby
  • Manufacturer: MTU
  • Model: 16V2000G36F
  • Engine Type: 4-stroke diesel
  • Injection Type: Direct
  • Aspiration Type: Turbocharged and after-cooled
  • Number of cylinders and arrangement: 16-V
  • Bore and Stroke: 135 x 156 mm
  • Displacement: 35,7 L
  • Cooling System: Water
  • Lube Oil Specifications: ACEA E4, E6, E7, E9
  • Compression Ratio: 17,5
  • Fuel Consumption ESP: 246,86 l/h
  • Fuel Consumption 100% PRP: 223,26 l/h
  • Fuel Consumption 75 % PRP: 167,44 l/h
  • Fuel Consumption 50 % PRP: 115,70 l/h
  • Fuel Consumption 25 % PRP: 63,66 l/h
  • Lube oil consumption with full load: 0,8 % of fuel consumption
  • Total oil capacity including tubes, filters 114 L
  • Total coolant capacity: 150 L
  • Governor Type Electrical
  • Air Filter Type Dry
  • Low coolant level sensor
  • Exhaust gas compensator
  • Diesel engine
  • 4-stroke cycle
  • Water-cooled
  • 24V electrical system
  • Standard air filter
  • Standard fuel filter
  • Standard oil filter
  • Radiator with pusher fan
  • HTW sender
  • LOP sender
  • Electronic governor
  • Hot parts protection
  • Moving parts protection
  • Generator: STAMFORD
  • Model: HCI634K
  • Poles: 4
  • Connection type (standard): Star-series
  • Mounting type: S-0 18''
  • Insulation: H class
  • Enclosure (according IEC-34-5): IP23
  • Exciter system: Self-excited, brushless
  • Voltage regulator: A.V.R. (Electronic)
  • Bracket type: Single bearing
  • Coupling system: Flexible disc
  • Coating type: Standard (Vacuum impregnation)
  • - OPEN SET VERSION.
  • Steel chassis
  • Emergency stop button
  • Oil sump extraction kit
  • Anti-vibration shock absorbers
  • Chassis with integrated fuel tank
  • Fuel level gauge
  • Fuel tank drain plug
  • - ELECTRICAL SYSTEM.
  • Electric control and power panel with measurements devices and control unit (according to necessity and configuration)
  • Connection panel wired to the safety protection (open thermal magnetic protection and alarm)
  • Maintenance-free and anti-explosion battery
  • Battery Switch
  • Battery charger (standard on gensets with automatic control panels)
  • Water Jacket Heater with single phase pump
  • Battery charger alternator with ground connection
  • Starter battery/ies installed (cables and bracket included)
  • Ground connection electrical installation with connection ready for ground spike (not supplied)
  • - EXHAUST SYSTEM.
  • Maximum exhaust temperature: 545 ºC
  • Exhaust Gas Flow: 207 m3/min
  • Maximum allowed back pressure: 50 mbar
  • - NECESSARY AMOUNT OF AIR.
  • Intake air flow: 4572 m3/h
  • Cooling Air Flow: 24,37 m3/s
  • Alternator fan air flow: 1,614 m3/s
  • - STARTING SYSTEM.
  • Starting power: 7,5 kW
  • Starting power: 10,2 CV
  • Recommended battery: 200 Ah
  • Auxiliary Voltage: 24 Vdc
  • - FUEL SYSTEM
  • Fuel Oil Specifications: Diesel
  • - DIMENSIONS.
  • Length: 4.950 mm
  • Width: 2.021 mm

Power


kVA

1135
 
1230
Prime power  (601 - 2572)
Stand by  (660 - 2809)

kW

908
 
984
Prime power  (481 - 2058)
Stand by  (528 - 2247)
 

Sound level

 dB
 Distance (m)

 
 

dimensions


 
dimensions
Long (A)
495
Width (B)
202,10
High (C)
0
 

Weight


 
Weight
Weight with liquid in radiator and carter

0
 

Fuel capacity


 
 
0