HMW-2555 T5
2572 kVA Generator set Open Skid
Powered by: MTU
Alternator: MECC ALTE
Three phase | 50 Hz | Diesel |
- Engine Specifications 1.500 r.p.m.
- Rated Engine Output: 2200kW prp ; 2420kW standby
- Manufacturer: MTU
- Model: 20V4000G14F
- Engine Type: 4-stroke diesel
- Injection Type: Direct
- Aspiration Type: Turbocharged and after-cooled
- Number of cylinders and arrangement: 20-V
- Bore and Stroke: 170 x 210 mm
- Displacement: 95,4 L
- Cooling System: Water
- Lube Oil Specifications: S10 W40
- Compression Ratio: 16,5:1
- Fuel Consumption ESP: 543,09 l/h
- Fuel Consumption 100% PRP: 498,84 l/h
- Fuel Consumption 75 % PRP: 385,64 l/h
- Fuel Consumption 50 % PRP: 272,44 l/h
- Fuel Consumption 25 % PRP: 156,69 l/h
- Lube oil consumption with full load: 1 % of fuel consumption
- Total oil capacity including tubes, filters 390 L
- Total coolant capacity: 790 L
- Governor Type Electrical
- Air Filter Type Dry
- Inner diameter exhaust pipe: 251 mm
- Electronic management (ADEC)
- Low coolant level sensor
- Exhaust gas compensator
- Diesel engine
- 4-stroke cycle
- Water-cooled
- 24V electrical system
- Standard air filter
- Standard fuel filter
- Standard oil filter
- Radiator with pusher fan
- HTW sender
- LOP sender
- Hot parts protection
- Moving parts protection
- Generator: MECC ALTE
- Model: ECO46.2L4A
- Poles: 4
- Connection type (standard): Star - Parallel
- Mounting type: S-00 21"
- Insulation: H class
- Enclosure (according IEC-34-5): IP23
- Exciter system: Self-excited, brushless
- Voltage regulator: A.V.R. (Electronic)
- Bracket type: Double drive-shaft
- Coupling system: Elastic Coupling
- Coating type: Standard (Vacuum impregnation)
- - OPEN SET VERSION.
- Steel chassis
- Emergency stop button
- Oil sump extraction kit
- Anti-vibration shock absorbers
- Chassis with integrated fuel tank
- Fuel level gauge
- Fuel tank drain plug
- Fuel transfer pump (Optional)
- Steel industrial silencer -15db(A) attenuation (Optional)
- Steel residential silencer -35db(A) attenuation. (Optional)
- - ELECTRICAL SYSTEM.
- Electric control and power panel with measurements devices and control unit (according to necessity and configuration)
- Connection panel wired to the safety protection (open thermal magnetic protection and alarm)
- Maintenance-free and anti-explosion battery
- Battery Switch
- Battery charger (standard on gensets with automatic control panels)
- Heating resistor (standard on sets with automatic control panels)
- Battery charger alternator with ground connection
- Starter battery/ies installed (cables and bracket included)
- Ground connection electrical installation with connection ready for ground spike (not supplied)
- - EXHAUST SYSTEM.
- Maximum exhaust temperature: 530 ºC
- Exhaust Gas Flow: 438 m3/min
- Maximum allowed back pressure: 85 mbar
- - NECESSARY AMOUNT OF AIR.
- Intake air flow: 9720 m3/h
- Cooling Air Flow: 43,63 m3/s
- Alternator fan air flow: 2,25 m3/s
- - STARTING SYSTEM.
- Starting power: 7,5 x 2 kW
- Starting power: 10,2 x 2 CV
- Recommended battery: 400 Ah
- Auxiliary Voltage: 24 Vdc
- - FUEL SYSTEM
- Fuel Oil Specifications: Diesel
- - DIMENSIONS.
- Length: 7.300 mm
- Height: 2.762 mm
- Width: 2.280 mm
- Maximum shipping volume: 45,97 m3
- Weight with liquids in radiator and sump: 18.950 kg
Power
kVA
2572
2809
Prime power (601 - 2572)
Stand by (660 - 2809)
Stand by (660 - 2809)
kW
2058
2247
Prime power (481 - 2058)
Stand by (528 - 2247)
Stand by (528 - 2247)
Sound level
dB
Distance (m)
Distance (m)
dimensions
Long (A)
730
Width (B)
228
High (C)
276,20
Long (A)
287,40
Width (B)
89,76
High (C)
108,74
Weight
Weight with liquid in radiator and carter
18.950 41.784,75
18.950 41.784,75
Fuel capacity
0