HGM-1895 T5 BIO
1893 kVA COP Generator set Open Skid
Powered by: MTU
Alternator: LEROY SOMER
Three phase | 50 Hz | Biogas |
- Engine Specifications 1.500 r.p.m.
- Rated Engine Output: 2000kW cop
- Manufacturer: MTU
- Model: 20V4000L32
- Engine Type: 4-stroke Otto Cycle
- Injection Type: Carburization
- Aspiration Type: Turbocharged and after-cooled
- Number of cylinders and arrangement: 20-V
- Bore and Stroke: 170 x 210 mm
- Displacement: 95,3 L
- Cooling System: Coolant
- Lube Oil Specifications: SAE 40
- Compression Ratio: 13,9
- Fuel Consumption 100% PRP: 32.315.71 cfh
- Fuel Consumption 75 % PRP: 24.709.94 cfh
- Fuel Consumption 50 % PRP: 17.534.95 cfh
- Lube oil consumption with full load: 0,2
- Total oil capacity including tubes, filters 378 L
- Total coolant capacity: 790 L
- Governor Type Electrical
- Air Filter Type Dry
- Biogas Engine
- 4-stroke cycle
- Water-cooled
- 24V electrical system
- Dry air filter
- Remote radiator
- HTW sender
- LOP sender
- Electronic governor
- Hot parts protection
- Moving parts protection
- Generator: LEROY SOMER
- Model: LSA 53.2 M9
- Poles: 4
- Connection type (standard): Star
- Mounting type: S-00 21"
- Insulation: H class
- Enclosure (according IEC-34-5): IP23
- Exciter system: Self-excited, brushless
- Voltage regulator: A.V.R. (Electronic)
- Bracket type: Single bearing
- Coupling system: Flexible disc
- Coating type: Standard (Vacuum impregnation)
- - OPEN SET VERSION.
- Steel chassis
- Emergency stop button
- Anti-vibration shock absorbers
- Steel industrial silencer -15db(A) attenuation
- Steel residential silencer -35db(A) attenuation. (Optional)
- - GAS RAMP.
- Gas filter
- Double solenoid valve
- Gas pressure regulator
- Low pressure switch
- High pressure switch
- Inlet pressure manometer
- Outlet pressure manometer
- - ELECTRICAL SYSTEM.
- Electric control and power panel with measurements devices and control unit (according to necessity and configuration)
- Battery Switch
- Battery charger (standard on gensets with automatic control panels)
- Heating resistor (standard on sets with automatic control panels)
- Battery charger alternator with ground connection
- Starter battery/ies installed (cables and bracket included)
- Ground connection electrical installation with connection ready for ground spike (not supplied)
- - EXHAUST SYSTEM.
- Maximum exhaust temperature: 443 ºC
- Exhaust Gas Flow: 132,3 m3/min
- Maximum allowed back pressure: 60 mbar
- - NECESSARY AMOUNT OF AIR.
- Intake air flow: 7370 m3/h
- Cooling Air Flow: 36,7 m3/s
- Alternator fan air flow: 2,5 m3/s
- - STARTING SYSTEM.
- Starting power: 9 x 2 kW
- Starting power: 12,24 x 2 CV
- Auxiliary Voltage: 24 Vdc
- - FUEL SYSTEM
- Fuel Oil Specifications: Biogas
- - DIMENSIONS.
- Length: 9.777 mm
- Height: 2.775 mm
- Width: 2.150 mm
- Maximum shipping volume: 58,33 m3
- Weight with liquids in radiator and sump: 21.010 kg
Power
kVA
0
Stand by (80 - 1250)
kW
0
Stand by (80 - 1000)
COP
1893
1893
kW (730 - 2538)
kVA (730 - 2538)
kVA (730 - 2538)
Sound level
dB
Distance (m)
Distance (m)
dimensions
Long (A)
977,70
Width (B)
215
High (C)
277,50
Long (A)
384,92
Width (B)
84,65
High (C)
109,25
Weight
Weight with liquid in radiator and carter
21.010 46.327,05
21.010 46.327,05
Fuel capacity
0